Mint NextMove PCI Installation Manual Page 29

  • Download
  • Add to my manuals
  • Print
  • Page
    / 92
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 28
Input / Output 4-13MN1903
4.4.4 Digital outputs - X4
Location Breakout module, connector X4
Pin Name MintMT keyword / description
1 Shield Shield connection
2 DOUT6 OUTX.6
3 DOUT7 OUTX.7
4 DOUT8 OUTX.8
5 DOUT9 OUTX.9
6 DOUT10 OUTX.10
7 DOUT11 OUTX.11
8 - (NC )
9 - (NC)
10 Shield Shield connection
11 USR V+ Customer power supply
12 CGND Customer power supply ground
Description
Six general purpose optically isolated digital outputs.
Output current: 50mA maximum each output
Update frequency: Immediate
Each optically isolated output is designed to source current from the customer supplied
12-24V supply (USR V+) as shown in Figure 5. The use of shielded cable is recommended.
The CGND must be connected to the host PC’s GND. See section 4.5.3 for details about
connecting the USR V+ supply.
OUTX.6
USR V+
NextMove PCI
DOUT6
Output
module
CGND
Output
load
Breakout
module
2
11
X4
100
pin
cable
12
Figure 5 - Digit a l output circuit with standard ‘PNP’ current sourcing module - DOUT6 shown
1
12
Page view 28