4-24 Input / Output MN1933
7
2
3
9
Breakout
module
X17
7
2
Baldor HMI
Operator Panel
Twisted pairs Twisted pairs
T
R
T
R
End
node
7
2
3
9
7
2
3
9
24V
0V
6
5
CANopen
D-type
1
2
Power
supply
terminal
block
24V
0V
CAN+
CAN-
Breakout
module
X17
Figure 13 - Typical CANopen network connections
Note: The NextMove PCI-2 CAN channel is opto-isolated, so a voltage in the range
12-24 VDC must be applied to pin 5 of the CAN connector.
The configuration and management of a CANopen network must be carried out by a single
node acting as the network master. This role can be performed by the NextMove PCI-2 when
it is configured to be the Network Manager node (node ID 1), or by a third party CANopen
master device.
Up to 126 CANopen nodes (node IDs 2 to 127) can be added to the network by a
NextMove PCI-2 Manager node using the Mint NODESCAN keyword. If successful, the nodes
can then be connected to using the Mint CONNECT keyword. Any network and node related
events can then be monitored using the Mint BUS1 event.
Note: All CAN related Mint keywords are referenced to either CANopen or Baldor CAN
using the ‘bus dot parameter . Although the NextMove PCI-2 has a single physical
CAN bus channel that may be used to carry either protocol, Mint distinguishes
between the protocols with the ‘bus dot parameter. For CANopen the ‘bus dot
parameter must be set to 1.
Please refer to the Mint help file for further details on CANopen, Mint keywords and dot
parameters.